Room family

Hospitality floor plan templates

3 templates, 224 to 864 sf. DXF R2018, drawn in inches. Free, no signup.

Brewery Cellar 24'-0" x 36'-0", 864 sf
Download Brewery Cellar Open in editor

DWG (R2000, converted from the DXF and round-trip verified). PNG is the plan-view render.

Brewery Cellar

Hospitality - 24'-0" x 36'-0" interior, 864 sf - typical for this room type: 864 sf

Brewery Cellar floor plan template, 24'-0" x 36'-0", 864 sf
Brewery Cellar - plan view, 24'-0" x 36'-0"

Where the fermenters and brite tanks live. Vertical clearance, not floor area, is what usually decides this room, and CO2 collecting at low level is what makes it dangerous.

The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.

Size

Interior (W x D)24'-0" x 36'-0"
Floor area864 sf
Overall, outside face of wall24'-10" x 36'-10"
Workable range for this room type 200 to 8000 sf
Unitsinches

What is in it

Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.

Download

DXF (127 KB) DWG (47 KB) PNG (155 KB)

Codes cited on the sheet

  • verified ADA 2010 Standards 403.5.1 — The accessible route through the space has a clear width of not less than 36 in, reducing to 32 in only for a length of not more than 24 in at a point obstruction such as a door frame.
  • verified ADA 2010 Standards 404.2.4 — Door maneuvering clearance on the pull side of a front approach is 18 in beyond the latch side and 60 in deep. A door that lands tight into a corner is the most common reason a compliant plan fails on site.
  • unverified ANSI/ISEA Z358.1 (unverified section); OSHA 29 CFR 1910.151(c) — An emergency eyewash is reachable within 10 seconds of unobstructed travel from where caustic or acid is handled, which in a cellar is anywhere CIP happens.
  • unverified FDA Food Code 2022 Section 5-203.11 (unverified; confirmed via state verbatim adoptions) — A handwashing sink is provided, used for no other purpose, and located so that food employees can reach it conveniently from the areas where they work. A prep sink, a warewashing sink and a service sink do not substitute for it.
  • unverified FDA Food Code 2022 Section 5-203.13 (unverified; confirmed via state verbatim adoptions) — A service sink or curbed cleaning facility with a floor drain is provided, and a toilet or a urinal may not be used as one.
  • unverified local sewer use ordinance and pretreatment requirements; varies by jurisdiction (unverified) — Process wastewater is regulated for organic load and pH by the local sewer authority. Yeast, trub and spent CIP chemicals all go down the cellar drains.
  • unverified typical practice; OSHA general duty clause and local fire code CO2 provisions, which vary by jurisdiction (unverified sections) — Carbon dioxide from fermentation is heavier than air, odourless, and accumulates at low level. Low-level ventilation and CO2 monitoring with an alarm are what address it. This is the cellar's principal life safety hazard and it is invisible.

"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.

How this was checked

23 of 76 checks graded, zero defects. This template is published because it graded clean.

53 checks had nothing to measure on this sheet
  • bath bands do not scale
  • bath fixture order and reach
  • bath one door
  • bath privacy
  • bath sink first
  • building inside the setbacks
  • circulation share of the floor plate
  • circulation zones
  • commercial seating rules
  • declared minimum width
  • byte-identical rebuild
  • door count by kind
  • entry and garage reach the right rooms
  • entry reaches public and private
  • number of exits
  • exterior doors
  • exterior doors declared
  • flanker has a legitimate spot
  • flanking seats flank
  • garage bays
  • garage projection
  • garage room depth
  • daylight area for habitable rooms
  • heated vs programme
  • jog count
  • jog min dimension
  • laundry out of the public zone
  • lot record is consistent
  • master opposite garage
  • no ada in residential
  • no reentrant in room
  • outdoor equipment kept outdoors
  • plate in range
  • plumbing fixture count for the occupant load
  • porch exclusive
  • private rooms hang off the hall
  • public zone on the living level
  • room bands by ratio
  • room vs programme
  • rooms inside union
  • seat backs off glazing
  • seats face focus
  • seats face open floor
  • service room bands
  • sleeping level has a full bath
  • sofa anchor backs a wall
  • sofa only where commerce seats
  • spine serves every private room
  • rooms contained within their suite
  • tub before shower
  • walking route between rooms
  • walls trace outline
  • zone assigned

A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.

Brewhouse

Hospitality - 24'-0" x 32'-0" interior, 768 sf - typical for this room type: 768 sf

Brewhouse floor plan template, 24'-0" x 32'-0", 768 sf
Brewhouse - plan view, 24'-0" x 32'-0"

The hot side: mash tun, kettle and whirlpool with a trench drain running the floor. Vertical clearance for the grist handling and the vessel manways is what usually decides the room.

The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.

Size

Interior (W x D)24'-0" x 32'-0"
Floor area768 sf
Overall, outside face of wall24'-10" x 32'-10"
Workable range for this room type 260 to 6000 sf
Unitsinches

What is in it

Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.

Download

DXF (128 KB) DWG (47 KB) PNG (148 KB)

Codes cited on the sheet

  • verified ADA 2010 Standards 403.5.1 — The accessible route through the space has a clear width of not less than 36 in, reducing to 32 in only for a length of not more than 24 in at a point obstruction such as a door frame.
  • verified ADA 2010 Standards 404.2.4 — Door maneuvering clearance on the pull side of a front approach is 18 in beyond the latch side and 60 in deep. A door that lands tight into a corner is the most common reason a compliant plan fails on site.
  • verified NFPA 70 (NEC) 110.26(A)(1)(2)(3) and Table 110.26(A)(1) — Working space in front of electrical equipment is not less than 3 ft deep for 0 to 150 V Condition 1, 30 in wide or the width of the equipment, and 6 ft 6 in of headroom.
  • unverified ANSI/ISEA Z358.1 (unverified section); OSHA 29 CFR 1910.151(c) — An emergency eyewash is reachable within 10 seconds of unobstructed travel from where caustic or acid is handled.
  • unverified FDA Food Code 2022 Section 5-203.11 (unverified; confirmed via state verbatim adoptions) — A handwashing sink is provided, used for no other purpose, and located so that food employees can reach it conveniently from the areas where they work. A prep sink, a warewashing sink and a service sink do not substitute for it.
  • unverified FDA Food Code 2022 Section 5-203.13 (unverified; confirmed via state verbatim adoptions) — A service sink or curbed cleaning facility with a floor drain is provided, and a toilet or a urinal may not be used as one.
  • unverified local sewer use ordinance and pretreatment requirements; varies by jurisdiction (unverified) — Process wastewater from a brewery is high in organic load and low in pH, and most jurisdictions regulate its discharge to sewer -- pretreatment, pH adjustment, or a surcharge. The floor drains and the trench have to land somewhere legal.
  • unverified typical practice; OSHA general duty clause and local fire code CO2 provisions (unverified sections) — Carbon dioxide accumulates at low level and is an asphyxiation hazard in a brewery. Monitoring and ventilation at low level are what address it, and the risk is greatest in the cellar rather than in the brewhouse.

"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.

How this was checked

23 of 76 checks graded, zero defects. This template is published because it graded clean.

53 checks had nothing to measure on this sheet
  • bath bands do not scale
  • bath fixture order and reach
  • bath one door
  • bath privacy
  • bath sink first
  • building inside the setbacks
  • circulation share of the floor plate
  • circulation zones
  • commercial seating rules
  • declared minimum width
  • byte-identical rebuild
  • door count by kind
  • entry and garage reach the right rooms
  • entry reaches public and private
  • number of exits
  • exterior doors
  • exterior doors declared
  • flanker has a legitimate spot
  • flanking seats flank
  • garage bays
  • garage projection
  • garage room depth
  • daylight area for habitable rooms
  • heated vs programme
  • jog count
  • jog min dimension
  • laundry out of the public zone
  • lot record is consistent
  • master opposite garage
  • no ada in residential
  • no reentrant in room
  • outdoor equipment kept outdoors
  • plate in range
  • plumbing fixture count for the occupant load
  • porch exclusive
  • private rooms hang off the hall
  • public zone on the living level
  • room bands by ratio
  • room vs programme
  • rooms inside union
  • seat backs off glazing
  • seats face focus
  • seats face open floor
  • service room bands
  • sleeping level has a full bath
  • sofa anchor backs a wall
  • sofa only where commerce seats
  • spine serves every private room
  • rooms contained within their suite
  • tub before shower
  • walking route between rooms
  • walls trace outline
  • zone assigned

A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.

Walk-in Cold Storage

Hospitality - 14'-0" x 16'-0" interior, 224 sf - typical for this room type: 224 sf

Walk-in Cold Storage floor plan template, 14'-0" x 16'-0", 224 sf
Walk-in Cold Storage - plan view, 14'-0" x 16'-0"

A prefabricated cooler and often a freezer beside it, with 48 in of clear floor at the door so a loaded dolly can turn into it. The condensing unit's service clearance sits outside the box and is separate.

The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.

Size

Interior (W x D)14'-0" x 16'-0"
Floor area224 sf
Overall, outside face of wall14'-10" x 16'-10"
Workable range for this room type 96 to 1200 sf
Unitsinches

What is in it

Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.

Download

DXF (92 KB) DWG (32 KB) PNG (191 KB)

Codes cited on the sheet

  • verified ADA 2010 Standards 403.5.1 — The accessible route through the space has a clear width of not less than 36 in, reducing to 32 in only for a length of not more than 24 in at a point obstruction such as a door frame.
  • verified ADA 2010 Standards 404.2.4 — Door maneuvering clearance on the pull side of a front approach is 18 in beyond the latch side and 60 in deep. A door that lands tight into a corner is the most common reason a compliant plan fails on site.
  • unverified FDA Food Code 2022 Chapter 3 food temperature and storage provisions (unverified sections; confirmed via state verbatim adoptions) — Cold holding temperatures and the equipment that maintains them are set by the FDA Food Code, and the storage arrangement inside the box -- raw below ready-to-eat, product off the floor -- is what a health inspection actually looks at.
  • unverified typical practice / industry standard for walk-in refrigeration; also addressed in workplace safety regulation (unverified sections) — Every walk-in cooler and freezer door has an interior release that opens the door from inside without a key or special knowledge, regardless of any lock on the outside.
  • unverified typical practice; manufacturer installation requirements — Condensing unit service clearance sits outside the box and is set by the manufacturer, typically 24 to 36 in on the service side with free air at the coil face. It is not part of the box footprint and it is routinely omitted from the plan.

"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.

How this was checked

22 of 76 checks graded, zero defects. This template is published because it graded clean.

54 checks had nothing to measure on this sheet
  • bath bands do not scale
  • bath fixture order and reach
  • bath one door
  • bath privacy
  • bath sink first
  • building inside the setbacks
  • circulation share of the floor plate
  • circulation zones
  • commercial seating rules
  • declared minimum width
  • byte-identical rebuild
  • door count by kind
  • entry and garage reach the right rooms
  • entry reaches public and private
  • number of exits
  • exterior doors
  • exterior doors declared
  • flanker has a legitimate spot
  • flanking seats flank
  • garage bays
  • garage projection
  • garage room depth
  • daylight area for habitable rooms
  • heated vs programme
  • jog count
  • jog min dimension
  • laundry out of the public zone
  • lot record is consistent
  • master opposite garage
  • no ada in residential
  • no reentrant in room
  • outdoor equipment kept outdoors
  • plate in range
  • plumbing fixture count for the occupant load
  • porch exclusive
  • private rooms hang off the hall
  • public zone on the living level
  • room bands by ratio
  • room vs programme
  • rooms inside union
  • seat backs off glazing
  • seats face focus
  • seats face open floor
  • service room bands
  • sleeping level has a full bath
  • sofa anchor backs a wall
  • sofa only where commerce seats
  • spine serves every private room
  • rooms contained within their suite
  • tub before shower
  • walking route between rooms
  • walls trace outline
  • window geometry
  • zone assigned

A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.

Code sections are cited for drafting context only. A room drawn to a dimension in a model code is not a compliance determination: adoption, amendment and interpretation are local, and the governing edition in your jurisdiction may differ from the one cited. Nothing here is stamped or sealed. Verify against the code your project is permitted under and the actual specified products. See the license and terms.

Other room families

All 71 room templates

Start from the room, not a blank sheet.