Room family

Retail floor plan templates

2 templates, 35 to 352 sf. DXF R2018, drawn in inches. Free, no signup.

Fitting Room 5'-0" x 7'-0", 35 sf
Download Fitting Room Open in editor

DWG (R2000, converted from the DXF and round-trip verified). PNG is the plan-view render.

Fitting Room

Retail - 5'-0" x 7'-0" interior, 35 sf - typical for this room type: 20 sf

Fitting Room floor plan template, 5'-0" x 7'-0", 35 sf
Fitting Room - plan view, 5'-0" x 7'-0"

A private changing cubicle, with at least one accessible room carrying a 60 in turning space and a bench per ADA 803. The accessible one is roughly twice the size of the others.

The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.

Size

Interior (W x D)5'-0" x 7'-0"
Floor area35 sf
Overall, outside face of wall5'-9" x 7'-9"
Workable range for this room type 18 to 60 sf
Unitsinches

What is in it

Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.

Download

DXF (79 KB) DWG (27 KB) PNG (238 KB)

Codes cited on the sheet

  • verified ADA 2010 Standards 304.3.1 and 304.3.2 — A wheelchair turning space is either a 60 in diameter circle or a T shape within a 60 in square.
  • verified ADA 2010 Standards 305.3 — Clear floor space at any element a person must use is not less than 30 by 48 in.
  • verified ADA 2010 Standards 308 — Operable parts -- switches, thermostats, card readers, outlets a user must reach -- fall between 15 and 48 in above the floor.
  • verified ADA 2010 Standards 308 — Hooks and shelves in the accessible fitting room fall within the 15 to 48 in reach range. A hook at 60 in serves nobody seated.
  • verified ADA 2010 Standards 403.5.1 — The accessible route through the space has a clear width of not less than 36 in, reducing to 32 in only for a length of not more than 24 in at a point obstruction such as a door frame.
  • unverified ADA 2010 Standards 803 and 222 (verified standard; sections applied not quoted, so marked unverified) — Where dressing, fitting or locker rooms are provided, at least 5 percent but not fewer than one of each type in each cluster is accessible. The accessible room has a 60 in turning space, a bench complying with 903, and a 30 by 48 in clear floor space at the bench.

"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.

How this was checked

19 of 76 checks graded, zero defects. This template is published because it graded clean.

57 checks had nothing to measure on this sheet
  • bath bands do not scale
  • bath fixture order and reach
  • bath one door
  • bath privacy
  • bath sink first
  • block faces its wall
  • building inside the setbacks
  • circulation share of the floor plate
  • circulation zones
  • clearance drawing matches
  • commercial seating rules
  • declared minimum width
  • byte-identical rebuild
  • door count by kind
  • entry and garage reach the right rooms
  • entry reaches public and private
  • number of exits
  • exterior doors
  • exterior doors declared
  • flanker has a legitimate spot
  • flanking seats flank
  • garage bays
  • garage projection
  • garage room depth
  • daylight area for habitable rooms
  • heated vs programme
  • jog count
  • jog min dimension
  • laundry out of the public zone
  • lot record is consistent
  • master opposite garage
  • no ada in residential
  • no reentrant in room
  • outdoor equipment kept outdoors
  • plate in range
  • plumbing fixture count for the occupant load
  • porch exclusive
  • private rooms hang off the hall
  • public zone on the living level
  • room bands by ratio
  • room vs programme
  • rooms inside union
  • seat backs off glazing
  • seats face focus
  • seats face open floor
  • service room bands
  • sleeping level has a full bath
  • sofa anchor backs a wall
  • sofa only where commerce seats
  • spine serves every private room
  • rooms contained within their suite
  • tub before shower
  • walking route between rooms
  • wall blocks backed
  • walls trace outline
  • window geometry
  • zone assigned

A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.

Retail Stockroom

Retail - 16'-0" x 22'-0" interior, 352 sf - typical for this room type: 350 sf

Retail Stockroom floor plan template, 16'-0" x 22'-0", 352 sf
Retail Stockroom - plan view, 16'-0" x 22'-0"

Back-of-house shelving plus a receiving and processing area. Usually 15 to 25 percent of the sales floor, and the receiving zone is what is undersized.

The sheet carries the fixture clearances as drawn geometry on their own layer, with the dimension strings and room notes outside the walls.

Size

Interior (W x D)16'-0" x 22'-0"
Floor area352 sf
Overall, outside face of wall16'-9" x 22'-10"
Workable range for this room type 100 to 4000 sf
Unitsinches

What is in it

Every one is a block from the CADdillo library, inserted — not drawn for this sheet. Linked where the block has a library page.

Download

DXF (102 KB) DWG (36 KB) PNG (153 KB)

Codes cited on the sheet

  • verified ADA 2010 Standards 308 — Operable parts -- switches, thermostats, card readers, outlets a user must reach -- fall between 15 and 48 in above the floor.
  • verified ADA 2010 Standards 403.5.1 — The accessible route through the space has a clear width of not less than 36 in, reducing to 32 in only for a length of not more than 24 in at a point obstruction such as a door frame.
  • verified ADA 2010 Standards 404.2.4 — Door maneuvering clearance on the pull side of a front approach is 18 in beyond the latch side and 60 in deep. A door that lands tight into a corner is the most common reason a compliant plan fails on site.
  • verified NFPA 70 (NEC) 110.26(A)(1)(2)(3) and Table 110.26(A)(1) — Working space in front of electrical equipment likely to require examination while energized is not less than 3 ft deep for 0 to 150 V Condition 1, 30 in wide or the width of the equipment, and 6 ft 6 in of headroom. A panel in a stockroom will be blocked by stock unless the space is marked and enforced.
  • unverified IBC 2021 Chapter 32 high-piled combustible storage and NFPA 13 (unverified sections) — Storage height, aisle width and commodity classification affect the sprinkler design and, in high-piled storage, trigger additional requirements. Stacking to the ceiling in a stockroom designed for ordinary hazard is the failure mode.

"Verified" means the citation was checked against the source text we hold. "Unverified" means it has not been, and should be read as a pointer to look the section up rather than as a quotation of it.

How this was checked

22 of 76 checks graded, zero defects. This template is published because it graded clean.

54 checks had nothing to measure on this sheet
  • bath bands do not scale
  • bath fixture order and reach
  • bath one door
  • bath privacy
  • bath sink first
  • building inside the setbacks
  • circulation share of the floor plate
  • circulation zones
  • commercial seating rules
  • declared minimum width
  • byte-identical rebuild
  • door count by kind
  • entry and garage reach the right rooms
  • entry reaches public and private
  • number of exits
  • exterior doors
  • exterior doors declared
  • flanker has a legitimate spot
  • flanking seats flank
  • garage bays
  • garage projection
  • garage room depth
  • daylight area for habitable rooms
  • heated vs programme
  • jog count
  • jog min dimension
  • laundry out of the public zone
  • lot record is consistent
  • master opposite garage
  • no ada in residential
  • no reentrant in room
  • outdoor equipment kept outdoors
  • plate in range
  • plumbing fixture count for the occupant load
  • porch exclusive
  • private rooms hang off the hall
  • public zone on the living level
  • room bands by ratio
  • room vs programme
  • rooms inside union
  • seat backs off glazing
  • seats face focus
  • seats face open floor
  • service room bands
  • sleeping level has a full bath
  • sofa anchor backs a wall
  • sofa only where commerce seats
  • spine serves every private room
  • rooms contained within their suite
  • tub before shower
  • walking route between rooms
  • walls trace outline
  • window geometry
  • zone assigned

A single room on its own sheet is not a whole building, so the checks that grade a floor plate — exit counts, circulation share, fixture counts against an occupant load — have no subject here. They are listed rather than counted as passes.

Code sections are cited for drafting context only. A room drawn to a dimension in a model code is not a compliance determination: adoption, amendment and interpretation are local, and the governing edition in your jurisdiction may differ from the one cited. Nothing here is stamped or sealed. Verify against the code your project is permitted under and the actual specified products. See the license and terms.

Other room families

All 71 room templates

Start from the room, not a blank sheet.